Release 0.5.0 / 20 October 2026

Frequency, dose and recovery

A corrected elastomer pilot: signed stiffness, synchronized acquisition, thermal controls and specimen-level inference.

A material pilot with explicit limits

E02-F is an unregistered pilot, with no collected specimens or results. It is separate from the M03-D stiffening oscillator and the E01-S softening null. Conventional viscoelastic and Mullins-effect explanations remain rivals. Published Ecoflex experiments already report softening, recovery and thermal/rate effects.

Correct the readout before testing the mechanism

The primary observable is force–displacement tangent stiffness over a frozen strain interval, rate, preload and temperature. Define positive softening D = 1 − K/K₀. A secondary ringdown interpretation requires fixed effective mass, calibrated fixtures and a single underdamped mode.

fₙ = f𝒹 / √(1 − ζ²)
D = 1 − (fₙ/fₙ₀)²
At fixed mass and zero damping, a change from 100 to 95 Hz gives D=9.75%.

A driven resonance peak is not automatically the undamped natural frequency. Damping, fixture compliance and slip can imitate a material change. A readout must also be shown not to erase or write the memory it measures.

Frequency, cycles and duration

ArmFrequencyCyclesDuration
T10.5 Hz1,50050 min
T25 Hz1,5005 min
T35 Hz15,00050 min
T40.5 Hz1505 min

The specified waveform is ε(t)=0.25−0.25 cos(2πft), from 0 to 50% engineering strain. Peak strain rate is 0.785/s at 0.5 Hz and 7.854/s at 5 Hz. Matched cycle count and matched duration comparisons answer different questions; none isolates every mechanism.

Acquisition and controls

Use synchronized force and specimen displacement with a pilot-validated bandwidth and phase delay; ≥1 ksample/s/channel is a proposed target. The HX711 datasheet gives 10 or 80 samples/s: only 2 or 16 samples per cycle at 5 Hz. Do not assume this yields accurate loop work.

Include duration-matched shams, heat-only histories, calibrated temperature/gradient monitoring and probe-only controls. Determine the cooldown from observed thermal stability. A 24-hour destructive sweep must not overwrite specimens intended for seven-day recovery. Validate removable fixtures or allow the actual fixture time.

Plan power from the pilot

Six specimens per arm is a pilot. For a proposed two-percentage-point practical margin, sample size changes sharply with the true contrast and variance. These normal-approximation examples target 90% power for the lower two-sided 95% interval to exceed that margin; they omit batch effects, small-sample correction, attrition and multiplicity.

Specimen SDAssumed true contrastApproximate n per group
1 percentage points3 percentage points22
1 percentage points5 percentage points3
2 percentage points3 percentage points85
2 percentage points5 percentage points10
4 percentage points3 percentage points337
4 percentage points5 percentage points38

Freeze one primary time and the absolute D(T2)−D(T1) contrast. Ratios are secondary and require a nonzero, identified denominator. A positive effect would distinguish only the tested material models under these controls.

Protocol and data templates

Complete pilot protocol · Stiffness and power calculations · Specimen template · Raw time-series template · Readout template

Calibration before a numerical claim

The SI extension of M03-D is now explicit, with synthetic parameters only. Frequency ratios are conditional on the writing regime, recovery, saturation and controlled displacement. E02-F remains a separate material pilot.

Physical units and ratio limits · Prospective evidence gates